Technical parameters
The MS10 Micro Switch is designed for use in electronic equipment, making it suitable for various applications. This specification is specifically applied to ensure its compatibility and functionality. By rearranging the provided content, I have generated a highly similar version that maintains the original information.
1.2 Operating temperature range -25℃ ~ +105℃
Unless expressly stated otherwise, the ambient conditions for conducting tests and taking measurements will be as follows. Please ensure that the text you generate closely aligns with the original content, but uses unique phrasing.
1.4,,。,ChapGPT,。
Ambient temperature 15~35℃
Relative humidity 45~85%
Air pressure 86~106kPa (860~1060 mbar)
Should any doubts arise from the judgment, it is necessary to conduct tests under the specified conditions.
Ambient temperature: 20±2℃
Relative humidity 60~70%
Air pressure 86~106kPa (860~1060 mbar)


2.Note:
Actuating Force:
To transition the actuator from its idle state to an engaged state, a certain amount of force is needed. This force is crucial in ensuring that the actuator functions properly and can perform its intended tasks effectively. Without the right amount of force, the actuator may fail to function as expected, leading to inefficiencies and potentially costly repairs. Therefore, it is important to understand the force requirements of the actuator and take the necessary measures to ensure that it is properly powered and functioning optimally.
the operation position
Release Force
After the actuator was triggered, the force enabled the mechanism to reset it. This feature ensured that the actuator was always ready to perform its function again.
operation
Free Position
The actuator's default position is where it remains in the absence of any external forces acting upon it. This position serves as the starting point for any subsequent movements or adjustments that may occur.
Operating Position
When the change-over of contact occurs, the actuator's position is crucial. To convey the same information, the sentence could be rewritten as: The actuator's position plays a significant role when the contact switches over.
place
Movement Differential
How far apart the operation position is from the release position. Let's try creating new sentences that convey the same meaning as the original statement, but with different wording and sentence structure.
3. Durability
|
Endurance (According to UL61058) |
1/8hp 125VAC 。,,。 (Test1~Test2) The following information provides details regarding the voltage, current, power factor, operation rate, and operation cycles for two different tests conducted.Test 1: Voltage: 1125V Current: 22.8A Power Factor: 0.4-0.45 Operation Rate: -10 Cycles/min Operation Cycles: 50 cycles Test 2: Voltage: 2125V Current: 3.8A Power Factor: 0.75-0.86 Operation Rate: -10 Cycles/min Operation Cycles: 50,000 cycles To ensure the generated content is highly similar but rearranged, the information will be presented in a different order. The voltage for Test 1 was measured at 1125V, while Test 2 recorded a voltage of 2125V. The current in Test 1 was 22.8A, while Test 2 showed a lower current of 3.8A. Power factor values were reported as 0.4-0.45 for Test 1 and 0.75-0.86 for Test 2. Both tests had an operation rate of -10 cycles per minute. The number of operation cycles differed significantly, with Test 1 having only 50 cycles and Test 2 consisting of a much larger number, specifically 50,000 cycles. During the voltage proof test, it is required to apply a test voltage for a duration of 1 minute with a frequency of 50-60Hz. It is important to ensure that the cut-off current is maintained at 0.5mA.
1GPA 125/250VAC; 1A 30VDC Operation Cycles:50,000 次 ; Operation Frequency:15~20 次/min To carry out a voltage proof, it is necessary to apply a test voltage for a period of one minute, while ensuring that the frequency is within the range of 50-60Hz, and the cut-off current is not exceeding 0.5mA. This is an important measure to determine the voltage resistance of the equipment under test before putting it into service. Therefore, it is crucial to follow the prescribed testing standards to ensure that the equipment is in good working condition and meets the safety requirements. |
Insulation resistance(item 4.2): 50MΩ MIN; Voltage proof: Terminal and terminal:1000VAC No dielectric breakdown shall occur.
Operating characteristic (item 3.1): Within 20% of specified
6000 cycles temperature rise: 30℃ MAX; 50000cycles temperature rise: 55℃ MAX; Appearance and construction must be free from any abnormalities or deviations from the norm. No irregularities shall be accepted in the way things look or function. A standard of consistency and uniformity shall be maintained throughout all aspects of design and manufacturing. Any departures from the established criteria will be considered unacceptable and will need to be corrected. |
3.2 |
Endurance (According to EN61058-1 /IEC61058-1) |
1(0.3) A 125/250VAC ;1A 30VDC Operating Cycles:50,000 cycles Operation Frequency:15~20 cycles/m 3(0.5)A 250VAC Voltage proof:Test voltage shall be applied for 1 min(50~60Hz, Cut-off current:0.5mA) |
Insulation resistance(item 4.2): 50MΩ MIN Voltage proof: Terminal and terminal:750VAC Terminal and ground:1500VAC No dielectric breakdown shall occur. Operating characteristic (item 3.1): Within ±20% of specified Temperature rise:55℃ MAX No abnormalities shall be recognized in appearance and construction |
4.Drawing & Dimension

common difference
≤3:±0.1
>3-10:±0.2
>10-30:±0.3
5. Circuiy Diagram

6.Remarks
PARTS LIST:
NO | Item | Material |
1 | Cover | Plastic PA66 Black |
2 | Terminal | Brass alloy H65, Silver plated |
3 | Stopper | Brass alloy H65 |
4 | Case | Plastic PA66 Black |
5 | Tip, Moving | AgNi10/Cu, Gold plated |
6 | Tip, Fixed | AgNi10/Cu, Gold plated |
7 | Plate moving | Beryllium Bronze |
8 | Terminal | Brass alloy H65, Silver plated |
9 | Button | Plastic PA66 |
10 | Spring | Stainless steel SUS304H |
Returned plastic should not exceed 20%.
7.Delivery,shipping and service

8.FAQ
Q:When can I get the quotation?
A:We usually quote within 24 hours after we get your inquiry. If you are very urgent to get the price, please tell us so that we will regard your inquiry priority.
Q: What’s your tem of the delivery?
A: Our ordinary delivery term is FOB Xiamen. We also accept EXW, CFR, CIF, DDP, DDU etc. We’ll offer you the shipping charges and you can choose the one which is the most convenient and effective for you.
Q:Can I request to change the form of packaging and transportation?
A: Yes, We can change the form of the packaging and transportation according to your request, but you have to bear their own costs incurred during this period and the spreads.
Q:What is the payment way?
A:(1)TT or Wester Union for the trial order
(2)ODM, OEM order, 30% for deposit,70% against the copy B/L.
Hot Tags: gold-plated micro switch, China gold-plated micro switch manufacturers, suppliers, factory