Technical parameters
2.1 Durability
NO. | Item | Test conditions | Criteria |
2.5.1 | Cold | The switch should be tested at -40±2℃ for 96 hours. After the testing period, it should be allowed to rest in a normal room temperature and humidity environment for 1 hour. Within 1 hour of resting, measurements must be taken, ensuring that any water drops are removed. | Contact resistance(item 4.1): 100mΩ MAX Insulation resistance (item 4.2): 50MΩ MIN Voltage proof: (item 4.3) No dielectric breakdown shall occur. Operating characteristic (item 5.1): A wide range of operating characteristics falls within a ±10% tolerance of the specified value. To create a highly similar content, the above information can be rearranged as follows: "The operating characteristic variety encompasses a tolerance range of ±10% around the specified value." Appearance and construction must exhibit no irregularities or anomalies. |
2.5.2 | Dry heat | During the 96-hour test at 105±2℃, it is required that the switch remains in normal room temperature and humidity conditions for 1 hour before conducting any measurements within the following hour. | |
2.5.3 | Damp heat | After subjecting the switch to a 40±2℃ temperature and 90-95% relative humidity (RH) for a duration of 96 hours, it is necessary to allow the switch to remain undisturbed under normal room temperature and humidity conditions for a period of 1 hour. Following this, measurements must be taken within 1 hour of the switch being removed from the test environment, ensuring that any water drops are carefully eliminated. | |
2.5.4 | Change of temperature | After 20 cycles of following conditions the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. | |
2.5.5 | Salt mist | Switch shall be checked after following lest. 1) Temperature: 35±2℃ 2) Salt solution: 5±1% (solids by mass) 3) Duration: 24±1h After test, salt deposit shall be removed in running water | No remarkable corrosion shall be recognized in metal part |
2.3 Welding Performance
2.6.1 |
Solder ability | Switch test under such conditions and inspect after. 1)Variable temperature range :235±5℃; 2)Dip time:3±0.5s; |
The area of dip tin should capture the 95% impregnated area |
2.6.2 |
Resistance to soldering heat |
The switch will be inspect under such conditions below Temperature and impregnated time Trial measuretemperature(℃)Time(s)Slot welding method260±55±1Soldering method350±53±0.5
|
All of the appearance, motor functions, electrical properties are no abnormal. |
3.Drawing & Dimension

4. Circuiy Diagram

5.FAQ
Q:How long can I expect to get the sample?
A:After you pay the sample charge and send us confirmed files, the samples will be ready
for delivery in 1-3 days. The samples will be sent to you via express and arrive in 3-5 days.
Q:Do you have after-sale service?
A:Yes, Good after-sale service, handling the customer complaint and solve problem for customers.
Q:Have your products been exported?
A: Yes, they have been exported to USA, Canada, Australia, Russia,Chile,Panama,Nicaragua, UAE, Saudi Arabia,Egypt,Sri Lanka, Nigeria, Iran,Vietnam,
Indonisia,Singapore,Greece,Netherland,Georgia,Romania,Ireland, India, Thailand, Pakistan, Philippines, Singapore, HK,Taiwan...
Q:When can I get the price?
A:Usually we quote within 24 hours after we get your inquiry.
Hot Tags: micro switch with cul, China micro switch with cul manufacturers, suppliers, factory