Technical parameters

2.3 Operating Characteristics
Characteristics | Units | Standards | Note |
| N | 5±3 Max | Original 5±3. . |
Contact Force | N | 0.4 Min | Original 0.4 Min |
| mm | 3 Min | Original 3 Min |
Note:
Actuating Force:
To move the actuator from the free position, a certain amount of force is necessary.
the operation position
2.4 Electrical Specification
NO. | Items | Test conditions | Requirements |
2.4.1 | Contact Resistance | Shall be measured at 50VAC by voltage drop method after some operations without load. Applied position: Between terminal and terminal | 30mΩ MAX |
2.4.2 | Insulation Resistance | Test voltage:500VDC, measured after 1 min ±5s Applied position: 1)Between terminal and terminal 2)Between terminal and ground | 100MΩ MIN |
2.4.3 | Voltage proof | Following test voltages shall be applied for 1 min. (Cut-off current:0.5mA) 1)Between terminal and terminal : 1500VAC (50~60Hz) | No dielectric breakdown shall occur |
2.5 Environment Resistance
NO. | Item | Test conditions | Criteria |
2.5.1 | Cold | After testing at0±2℃ for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. | Contact resistance(item 4.1): 100mΩ MAX Insulation resistance (item 4.2): 50MΩ MIN Voltage proof: (item 4.3) No dielectric breakdown shall occur. Operating characteristic (item 5.1): Operating characteristic variety Within ±10% of specified value . No abnormalities shall be recognized in appearance and construction. |
2.5.2 | Dry heat | After testing at 85±2℃ for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. | |
2.5.3 | Damp heat | After testing at 40±2℃ and 90-95%RH for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. | |
2.5.4 | Change of temperature | After 20 cycles of following conditions the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. | |
2.5.5 | Salt mist | Switch shall be checked after following lest. 1) Temperature: 35±2℃ 2) Salt solution: 5±1% (solids by mass) 3) Duration: 24±1h After test, salt deposit shall be removed in running water | No remarkable corrosion shall be recognized in metal part |
3. Drawing & Dimension

4. Circuiy Diagram

5.Product application
Home / Household Appliances
Electric kettle, Robot cleaner, Dust catcher, Vacuum cleaner, Coffee maker, Running machine etc.
Electronic Equipment
Toys, Power tools, Car control panel etc.
Medical Equipment
Communication Equipment
Automation Equipment
Automotive Electronics
Instrumentation
6.Remarks
PARTS LIST:
ITEM | NAME | MATERIAL |
1 | Base | Plastic |
2 | Button | Plastic |
3 | Terminal | Brass alloy H65,Tin Plated |
4 | Moving piece | Brass alloy H65,Silver Plated |
5 | Spring | Carbon spring steel thread,nickel plated |
6 | Light | Neon lamp-Red |
Returned plastic should not exceed 20%.
8.FAQ
Q:When can I get the quotation?
A:We usually quote within 24 hours after we get your inquiry. If you are very urgent to get the price, please tell us so that we will regard your inquiry priority.
Q: Which payment form you can accept?
A: T/T, L/C, Western Union, PayPal etc. We accept any convenient and swift payment term.
Q: How many packaging do you have?
A: We have three packages including bag, carton, barrel, usually it is
Q:Would you have a discount if l have a large order?
A:Yes we could offer different discount according to your order quantity.
Hot Tags: rocker switch waterproof cover, China rocker switch waterproof cover manufacturers, suppliers, factory