Technical parameters 2.1 General 2.1 General 2.1.1 Application The application of this specification pertains to the utilization of TACT Switches in electronic equipment. It is important to ensure that the generated content is highly similar by rearranging the original information. 2.1.2...

Technical parameters

2.1 General

2.1 General
2.1.1 Application
The application of this specification pertains to the utilization of TACT Switches in electronic equipment. It is important to ensure that the generated content is highly similar by rearranging the original information.
2.1.2 Operating temperature range -20℃ ~ +70℃
The recommended storage temperature range for this product is from -30℃ to +85℃. It is crucial to store and handle this product within this temperature range in order to maintain optimal performance and ensure longevity. Any deviation from this range could potentially cause irreversible damage to the product and result in failure. So always make sure to store this product in a cool, dry place that is free from any extreme temperatures that may negatively impact its functionality.
In order to carry out a proper test, certain conditions must be met. These conditions are crucial to obtaining accurate and reliable results. Test conditions refer to various factors that can influence the outcome of a test. For instance, the environment in which the test is conducted, the equipment used, and the participants in the test are all significant factors that must be taken into consideration when setting up the test conditions. The aim of test conditions is to minimize any external variables that could affect the test results and to make sure that the test is conducted under standardized conditions. This ensures that any differences found in the test results are solely due to the independent variable being tested. Therefore, it is important to carefully plan and implement the test conditions before carrying out any tests.
Ambient temperature 5~35℃
Relative humidity 45~85%
Air pressure 86~106kPa (860~1060 mbar)
If there are any doubts regarding the judgment, it is necessary to conduct tests under the following conditions.
Ambient temperature: 20±2℃
Relative humidity 60~70%
Air pressure 86~106kPa (860~1060 mbar)
2.2 Appearance construction and dimensions
The Appearance Switch should exhibit excellent finishing, with no signs of rust, cracks, or plating failures.
The construction and dimensions of the product can be found on the individual product drawing. It is important to refer to the drawing to understand the specific construction details and dimensions of the product. Please make sure to review the drawing carefully to ensure accurate information about the construction and dimensions of the product.

2.3. ELECTRICAL SPECIFICATION

NO.

Items

Test conditions

Requirements

2.3.1

Contact
resistance

Shall be measured at 10mA 5VDC by
voltage drop method after some

operations without load.

Applied position: Between terminal and terminal

50mΩ MAX

2.3.2

Insulation
resistance

Test voltage:250VDC, measured after 1 min ±5s

Applied position: 1)Between terminal and terminal 

2)Between terminal and ground

100MΩ MIN

2.3.3

Dielectric
voltage proof

Following test voltages shall be applied for 1 min.

(Cut-off  current:0.5mA)

1)Between terminal and terminal :250VAC (50~60Hz)

No dielectric breakdown

shall occur.

2.3.4

Contact bounce

Lightly striking the center of the stem
at a rate encountered in normal use

(3 to 4 times per second), and bounce
shall be tested at “ON” and “OFF” 

01

ON-3msec.max

OFF-8msec.max

 

2.4. ENVIRONMENT RESISTANCE:

NO.

Items

Test conditions

Requirements

2.4.1

Resistance to

low temperature

Following the test set forth below the
sample shall be left in normal temperature

and humidity conditions for 1 h. Before
measurements are made:

1)Temperature:-30±2℃

2)Time: 96h

Contact resistance: 

200mΩ MAX

Insulation resistance:

50MΩ MIN

Voltage proof:

No dielectric
breakdown shall occur.

Operating characteristic variety

Within ±10% of specified value.

2.4.2

Heat resistance

Following the test set forth below the
sample shall be left in normal temperature

and humidity conditions for 1h before
measurements are made:

1)Temperature:-80±2℃

2)Time: 96h


2.4.3

Moisture
resistance

Following the test set forth below the
sample shall be left in normal temperature

and humidity conditions for 1h before
measurements are made:

1)Temperature: 60±2℃

2)Relative humidity: 90 to 95%

3)Time:96h


2.4.4

Change of

temperature

After 5 cycles of following conditions, the
sample shall be allowed to stand under

normal temperature and humidity conditions
for 1h and measurements shall be

made. During the test waterdrops shall be removed.

 02

 2.4.5

Sulfuration

resistance

Following the test set forth below the
sample shall be left in normal temperature

and humidity conditions for 1h before
measurements are made:

1)H2S gas concentrations: 3ppm±1ppm;

2)Time:8h;3)Temperature: 40±2℃(90~95%RH)


2.4.6

Salt mist

The switch shall be checked after following test:

1)Temperature: 35℃±2℃

2)Salt solution : 5±1%(solids by mass)

3)Time: 8±1 hour

After test, salt deposit shall be removed by running water.

No remarkable corrosion shall

be recognized in metal part.

2.5. WELDING PERFORMANCE

2.5.1

Solderability

Switch test under such conditions and inspect after.

1)Variable temperature range :245±5℃;

2)Dip time:2±0.5s;

Except for the
edge, the coating

should cover a
minimum 90%

2.5.2

Resistance
eat soldering

The switch will be inspect under such conditions below

05

 

There shall be
no sign of damage

mechanically
and electrically.

2.6. DURABILITY


2.6.1

Operation life

Measurement shall be made following the test set forth below:

DC 12V, 50 mA resistance load;

Rate of operation:40-60 times/min;

Operating Force:320~350gf; 

Average fault-free life: 100,000 cycles

Contact resistance:

≤200mΩ

Contact bounce:

≤10ms

Operating Force:

initial value±30%

 

2.6.2

Vibration

Measurement shall be made following the test set forth below:

1) Vibration frequency range: 10Hz to 55Hz to 10Hz;

2) Amplitude: 1.5mm; 

3) Direction of vibration: three mutually perpendicular direction

including the direction of stem travel

4) Duration: Each 2hours.


2.6.3

Operation
Force

The switch is placed perpendicular to the direction of the operation,

gradually force in key top center of switch, measure maximum

intensity when it conducted required.

160±50gf

2.6.4

Over Travel

Switch at the vertical operating orientation placement, with a force

equal to 2 times according to the static load applied on the switch

button the top center, measure the top moving distance

0.25±0.10mm

2.6.5

Return force

The sample switch is installed such that the direction of switch

operation is vertical and upon depressing the stem in its center to

the whole travel distance, the force of the stem to return to its

free position shall be measured.

60gf.min.

2.6.6

Stop strength

Placing the switch such that the direction of switch operation is

vertical, and then a static load of 30N shall be applied in the 

direction of stem operation for a period of 1 min.

There shall be
no sign of damage

mechanically
and electrically.

2.6.7

Stem strength

Placing the switch such that the direction of switch operation is

vertical, and then the maximum force to withstand a pull applied

opposite to the direction of stem operation shall be measured.

20N.min.

3. DRAWING & DIMENSION:

1(1)

4.Product application

Consumer products
Communication equipments

Widely used in home appliance, electronic equipment, automatic machine, 
communication equipment, car electron, apparatus and instrument, electric motion tool etc.

5.Remarks

PARTS LIST:

NO.  

NO.

NAME

MATERIAL

1

1

Terminal

Brass silver plating

2

1

Case

PA66  

3

1

Spring plate

SUS301 silver plating

4

1

Stem

PA66

5

1

LED

GaP

Returned plastic should not exceed 20%.