Technical parameters
2.1 General
2.2 Appearance construction and dimensions
The Switch's appearance should display excellent finishing and lack any signs of rust, cracks, or plating failures.
Construction and dimensions must be determined by referring to the specific product drawing. It is important to carefully analyze the drawing to understand the precise structure and measurements of the product. This information is vital for accurate manufacturing and assembly processes. By adhering to the details provided in the product drawing, one can ensure that the construction and dimensions are aligned with the original design specifications. Therefore, it is crucial to refer to the individual product drawing to obtain the necessary information for constructing and measuring the product accurately.
2.3. ENVIRONMENT RESISTANCE
NO. | Items | Test conditions | Requirements |
2.3.1 | Low Temperature | Following the completion of the -20±3℃ testing for a duration of 96 hours, the switch must be left untouched for one hour while being exposed to normal room temperature and humidity conditions. Within one hour of the switch being left to stand, measurements must be taken, ensuring that any water droplets are removed beforehand. It is essential to note that the content generated must be similar to the original text while using different sentence structures and phrasing. | (1)Contact resistance: 50mΩ MAX
(2)Insulation resistance: 100MΩ MIN
(3)Voltage proof: No dielectric breakdown shall occur.
(4)Operating characteristic: One important aspect to consider when evaluating operating characteristics is the variety that can arise when measurements fall within a range of ±10% of the specified value. It is crucial to ensure that equipment is accurately calibrated in order to minimize the potential for variance and ensure consistency in performance. By maintaining strict control over operating characteristics, organizations can achieve greater reliability in their operations and enhance overall productivity.
The appearance and construction must not show any anomalies or deviations from the norm. |
2.3.2 | High Temperature | Once subjected to a temperature of 70±2℃ for a period of 96 hours, the switch must be left to acclimate to normal room temperature and humidity conditions for a minimum of 1 hour before any measurement is conducted within the same hour. | |
2.3.3 | Steady Damp-heat | Upon conducting a 96-hour test under temperature of 40±2℃ and relative humidity of 90-95%, the switch must be left to stand under normal room temperature and humidity conditions for 1 hour. After such time, measurements should be taken within an hour while ensuring all water droplets have been removed. It is imperative to observe these procedures to ensure accurate results and prevent potential hazards. | |
2.3.4 | Change of temperature | After 5 cycles of following conditions the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. | |
2.3.5 | Salt mist | he switch shall be checked after following test: 1) Temperature: 35℃±2℃ 2) Salt solution : 5±1%(solids by mass) 1) Time: 24±1 hour After test,salt deposit shall be removed by running water.
|
2.4 DURABILITY
|
Life Test | An actuator shall be with a thrust of no great than 1 times switch power to 3,000 cycles. At a speed of 30 cycles for 1 minutes. |
1)Contact resistance: 50mΩ MAX 2) Life time: 3) 3000 cycles |
2.4.2 | Stem Strength | And along the running direcition at apex handle (500g) on the strength test, time is 30 seconds. |
3. DRAWING & DIMENSION

5.Remarks
PARTS LIST:
NO. | NO. | NAME | MATERIAL |
1 | 1 | Actuator | Thermo Plastic PBT UL94V-0 |
2 | 1 | Cover | Thermo Plastic PBT UL 94V-0 |
3 | 1 | Contact | Phosphor Bronze |
4 | 1 | Terminal | Bronze Cold Plated |
5 | 1 | Base | Thermo Plastic PBT UL 94V-0 |
Returned plastic should not exceed 20%.
6.Delivery,shipping and service
7.FAQ

Hot Tags: 2 pin dip switch, China 2 pin dip switch manufacturers, suppliers, factory


