Technical parameters
2.1 General

2.3 Operating Characteristics
Characteristics | Units | Standards | Note |
| N | 4±1.5 Max | Original 4±1.5 . |
Contact Force | N | 0.4 Min | Original 0.4 Min |
| mm | 3 Min | Original 3 Min |
Note:
Actuating Force:
To move the actuator from a free state to a locked state, a certain amount of force is required.
the operation position
2.4 Electrical Specification
NO. | Items | Test conditions | Requirements |
2.4.1 | Contact Resistance | Shall be measured at 12A 24VDC by voltage drop method after some operations without load. Applied position: Between terminal and terminal | 35mΩ MAX |
2.4.2 | Insulation Resistance | Test voltage:500VDC, measured after 1 min ±5s Applied position: 1)Between terminal and terminal 2)Between terminal and ground | 100MΩ MIN |
2.4.3 | Voltage proof | Following test voltages shall be applied for 1 min. (Cut-off current:0.5mA) 1)Between terminal and terminal :1250VAC/min (50~60Hz)
| No dielectric breakdown shall occur |
2.5 Environment Resistance
NO. | Item | Test conditions | Criteria |
2.5.1 | Cold | After testing at -25±2℃ for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. | Contact resistance(item 4.1): 100mΩ MAX Insulation resistance (item 4.2): 50MΩ MIN Voltage proof: (item 4.3) No dielectric breakdown shall occur. Operating characteristic (item 5.1): Operating characteristic variety Within ±10% of specified value . No abnormalities shall be recognized in appearance and construction. |
2.5.2 | Dry heat | After testing at 105±2℃ for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. | |
2.5.3 | Damp heat | After testing at 40±2℃ and 90-95%RH for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. | |
2.5.4 | Change of temperature | After 20 cycles of following conditions the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. | |
2.5.5 | Salt mist | Switch shall be checked after following lest. 1) Temperature: 35±2℃ 2) Salt solution: 5±1% (solids by mass) 3) Duration: 24±1h After test, salt deposit shall be removed in running water | No remarkable corrosion shall be recognized in metal part |
2.6 Welding Characteristics
2.6.1 |
Solder ability | Switch test under such conditions and inspect after. 1)Variable temperature range :235±5℃; 2)Dip time:3±0.5s; |
The area of dip tin should capture the 95% impregnated area |
2.6.2 |
Resistance to soldering heat |
The switch will be inspect under such conditions below Temperature and impregnated time Trial measuretemperature(℃)Time(s)Slot welding method260±55±1Soldering method350±53±0.5
|
All of the appearance, motor functions, electrical properties are no abnormal. |
2.7 Durability
NO. | Item | Test condition | Criteria |
2.7.1 | Endurance (According to UL61058) | 12A 125VAC Switch shall be operated according to following sequence (Test1~Test2) VoltageCurrentPower factorOperation rateNumber of operationTest1125V14A0.75-0.86-10cycles/min50cyclesTest2125V12A0.75-0.86-10cycles/min6000cyclesVoltage proof(Cut-off current:0.5mA) 1GPA 125/250VAC ; Switch shall be operated 6,000 cycles at 15-20 cycles/min. Test voltages shall be applied for 1 min | Insulation resistance(item 4.2): 30MΩ MIN Voltage proof: Terminal and ground:1000VAC No dielectric breakdown shall occur. Operating characteristic (item 5.1): Operating characteristic variety Within ±20% of specified value . 6000 cycles temperature rise:30℃ MAX; 10,000 cycles temperature rise:55℃ MAX;
No abnormalities shall be recognized in appearance and construction |
2.7.2 | Endurance (According to EN61058-1 /IEC61058-1) | 16 (8) A 250VAC Switch shall be operated 10,000 cycles at 15~20 cycles/min Voltage proof(Cut-off current:0.5mA) Test voltages shall be applied for 1 min. | Insulation resistance(item 4.2): 50MΩ MIN Voltage proof: Terminal and terminal:750VAC Terminal and ground:1500VAC No dielectric breakdown shall occur. Operating characteristic (item 5.1): Operating characteristic variety Within ±20% of specified value . Temperature rise:55℃ MAX No abnormalities shall be recognized in appearance and construction |
3.Drawing & Dimension

4. Circuiy Diagram

5.Product application

6.Remarks
PARTS LIST:
ITEM | NAME | MATERIAL |
1 | Button | Plastic |
2 | Base | Plastic |
3 | Terminal | Brass alloy H65,Silver Plated |
4 | Plate moving | Brass alloy H65,Silver Plated |
5 | Contact | Silver-Cadmium Oxide alloy |
6 | Contact | Silver-Cadmium Oxide alloy |
7 | Spring | Manganese Steel |
8 | Steel Ball | Stainless Steel |
Returned plastic should not exceed 20%.
7.Delivery,shipping and service

8.FAQ

Hot Tags: double rocker light switch, China double rocker light switch manufacturers, suppliers, factory