Technical parameters
2.1 General

2.3 Operating Characteristics:
Characteristics | Units | Standards | Note |
| N | 4±1.5 Max | Original 4±1.5 . |
Contact Force | N | 0.4 Min | Original 0.4 Min |
| mm | 3 Min | Original 3 Min |
Note:
Actuating Force:
To move the actuator from its free position, a certain amount of force is needed. This force may vary depending on factors such as the size of the actuator, the weight of the load it is moving, and the type of mechanism used to apply the force. Regardless of these factors, it is important to ensure that the force applied is sufficient to move the actuator smoothly and efficiently. Failure to apply enough force may result in the actuator sticking or failing to move altogether. Therefore, it is vital to determine the required force for each actuator and apply it accordingly.
the operation position
2.4 Electrical Specification:
NO. | Items | Test conditions | Requirements |
2.4.1 | Contact Resistance | Shall be measured at 12A 24VDC by voltage drop method after some operations without load. Applied position: Between terminal and terminal | 30mΩ MAX |
2.4.2 | Insulation Resistance | Test voltage:500VDC, measured after 1 min ±5s Applied position: 1)Between terminal and terminal 2)Between terminal and ground | 100MΩ MIN |
2.4.3 | Voltage proof | Following test voltages shall be applied for 1 min. (Cut-off current:0.5mA) 1)Between terminal and terminal :2000VAC/min (50~60Hz) 2)Between terminal and ground: 2500VAC/min (50~60Hz) | No dielectric breakdown shall occur |
2.5 Environment Resistance:
NO. | Item | Test conditions | Criteria |
2.5.1 | Cold | After testing at -25±2℃ for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. | Contact resistance(item 4.1): 100mΩ MAX Insulation resistance (item 4.2): 50MΩ MIN Voltage proof: (item 4.3) No dielectric breakdown shall occur. Operating characteristic (item 5.1): Operating characteristic variety Within ±10% of specified value . No abnormalities shall be recognized in appearance and construction. |
2.5.2 | Dry heat | After testing at 105±2℃ for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. | |
2.5.3 | Damp heat | After testing at 40±2℃ and 90-95%RH for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. | |
2.5.4 | Change of temperature | After 20 cycles of following conditions the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. | |
2.5.5 | Salt mist | Switch shall be checked after following lest. 1) Temperature: 35±2℃ 2) Salt solution: 5±1% (solids by mass) 3) Duration: 24±1h After test, salt deposit shall be removed in running water | No remarkable corrosion shall be recognized in metal part |
3.Drawing & Dimension:

4. Circuiy Diagram:

5.Product application
Home / Household Appliances
Electric kettle, Robot cleaner, Dust catcher, Vacuum cleaner, Coffee maker, Running machine etc.
Electronic Equipment
Toys, Power tools, Car control panel etc.
Medical Equipment
Communication Equipment
Automation Equipment
Automotive Electronics
Instrumentation
6.Remarks
PARTS LIST:
Item | Name | Material |
1 | House | Nylon |
2 | Shaft | Nylon |
3 | Button | Nylon |
4 | Soldering Terminal | Brass Strip |
5 | Moving Terminal | Bronze Strip |
6 | Support | Copper Strip |
7 | Compressed Spring | Stainless Steel Wire |
8 | Top Column | Brass Strip |
9 | Contact | AgCdO / Copper |
10 | LED | LED |
Returned plastic should not exceed 20%.